Depending on the system design, a PV installation requires safe isolation on both the DC and AC sides. A DC switch disconnector separates the modules from the inverter. An AC switch disconnector is installed on the grid side.
For three-phase PV systems where the neutral must also be switched, plica deliberately offers 3P+N AC switch disconnectors. The dedicated neutral pole closes before the phases and opens after them.

Both descriptions refer to a device with four current paths. The function of the fourth pole is what matters.
In a general 4P version, all four poles are treated as equivalent switching poles. Without a defined neutral function, the fourth pole is not automatically guaranteed to close first and open last.
With 3P+N, the fourth pole is expressly designed as the neutral pole. The Scame versions used have an early-make and late-break neutral function.
In a three-phase PV installation with neutral, the defined sequence prevents the phases from being momentarily connected without a neutral. plica therefore uses 3P+N versions for AC switch disconnectors with neutral.
A 3P+N device is technically also four-pole. Some manufacturers therefore state 4P (3P+N). The data sheet must confirm the early-make / late-break neutral function.
The DC switch disconnector is installed between the PV generator and inverter. It must be rated for the DC voltage, string current and switching concept.
The AC switch disconnector is installed on the grid side of the inverter. A 3P+N version is used where the neutral must also be switched.
The compact TP version shown combines clear position indication with generous wiring space and flexible cable entries.


The short plica video presents the robust design, clear operation and installer-friendly details.
Open video on YouTube3P+N is suitable when the three phases and neutral must be isolated together on the AC side. Whether the neutral must be switched depends on the earthing system, system design and inverter requirements.
When switching on, the neutral closes before the phases. When switching off, it opens after them.
A device may have four poles without a dedicated neutral sequence. The 3P+N function must be explicitly confirmed.
The PV category includes 3P+N AC switch disconnectors from 16 A to 1600 A and separate DC switch disconnectors from 16 A to 40 A.
Choose between 3P+N AC switch disconnectors and dedicated DC switch disconnectors.